资源预览内容
第1页 / 共39页
第2页 / 共39页
第3页 / 共39页
第4页 / 共39页
第5页 / 共39页
第6页 / 共39页
第7页 / 共39页
第8页 / 共39页
第9页 / 共39页
第10页 / 共39页
亲,该文档总共39页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述
OPERATION MANUAL FIREALARMSYSTEM AFMS-3000 * * Technical Documentation Fire alarm system AFMS-3000 for sea-going vessels Modification level Version Date Author Approved Remarks 01 03.01.07 STO HN 1st issue 02 22.05.07 STO HN Software version 3.2 OPERATION MANUAL FIREALARMSYSTEM AFMS-3000 * * Table of contents 1. Structure of the plant 1.1 Construction 3 1.2 Data storing 4 1.3 Fire and Fault detection 4 2. Description of the System 2.1 FMS 3000 TR01-E Transformer module 5 2.2 FMS 3000 NM01-E Power Supply module 6 2.3 FMS 3000 AM01-E Output module 7-8 2.4 FMS 3000 FM01-E Fire detector module 9-10 2.5 FMS 3000 AFM01-E Fire detector module addressable 11-12 2.6 FMS 3000 DM01-E Printer Module 13 2.7 FMS 3000 VM01-E VDR module 14 2.8 FMS 3000 AHT01-E Main panel graphic 15-16 2.9 FMS 3000 DT01-E Data module 17 2.10 FMS 3000 HT01-E Main/Repeater panel 18 2.11 FMS 3000 MM-01E Mimik module 19 2.12 AFMS 3000 SM01-E Slave module 20 3. Indication and operation from Graphic Panel AHT01-E 21 3.1 Indication Grafikdisplay 22 3.2 Function keys 23 3.3 Number keypad, backspace and enter 24 3.4 Keys Fire, Fault and Reset 25 3.5 Indicators Fire, Fault and Reset 26 3.6 Indicator Alarm in Sequins 27 3.7 Indicators Mains, Disconnect, Pre Alarm and Test modus 28 4. Operating of the AFMS 3000 with AHT01-E Graphic Panel 4.1 Fire alarms 29-30 4.2 Fault alarms 31-32 4.3 Main menu 33 4.4 Indicating the actual firmware 33 4.5 Reset of the AFMS 3000 33 4.6 Adjusting Time and date 33 7 Lamp est 34 4.8 Adjusting background light of display 34 4.9 Adjusting the display light 34 4.10 Adjusting the green background light 34 4.11 Adjusting the alarm indicator light 34 4.12 Change the operator code 34 4.13 Activating the One-man-test 35 4.14 Deactivation of detector, Zones or outputs 35 4.15 Adjusting the delay time of detectors 35 4.16 Adjusting the intensity of detectors 35 4.17 Overview of detector status 35 7.0 Mechanica specification 36-39 8.0 Schematic system overview 40 9.0 Drawings 41 and following OPERATION MANUAL FIREALARMSYSTEM AFMS-3000 1.1 Construction The fire alarm system is developed as a modular system. The individual modules are connected by an internal bus and a common voltage supply (24V). All modules, with exception of the Main- and repeater Panels are intended for the mounting rail assembly. The Main- and repeater Panel are design for recess mounting into a Desk Panel. These single modules are built together in a metal switchgear cabinet. The system can be design alternatively for the wall mounting or for recessed mounting when using the Main panel as an external unit to fit directly into the Panel. The modular structure and the bus system are identical to the existing fire alarm system FMS3000. Likewise some modules are used by the FMS-3000 invariably and some modules modified in the AFMS-3000. For AFMS-3000 necessary new modules has the same design as the FMS-3000 and wise on same places also the same details up. (E.g. relay outputs at the modules are implemented with the same relays and the same terminal connection) The system is organized according to the master Slave principle. That means that a master module gets Information from the slave modules, the information on evaluates and administers and actions the slave modules releases. In the AFMS-3000 the graphic display module functions as master. This is direct with a data module (not over the general bus system) connected, which stores on a SD-memory card data and this makes available. A SFMS-3000 (smoke detection system) and/or OFMS-3000 (Local protection system) attached to the AFMS-3000 in the AFMS-3000 as a slave module one administers in each case. At the SFMS-3000 or OFMS-3000 attached modules are administered by these. I.e. for these modules the fan module is and with the OFMS-3000 the power pack module of the masters. Example Flush mounting version Anschlussbox/ SchaltschrankNetzteil ModulAusgangs Modul 1Haupttableau(erforderlich fr jede Anlage)Trafo ModulFeuermelde Modul 1 Feuermelde Modul 2(erforderlich fr 2 Schleifen) (erforderlich fr 4 Schleifen)(erforderlich fr jede Anlage)(erforderlich fr jede Anlage)(erforderlich fr jede Anlage)Paralleltableau 1 Paralleltableau 2(Optional) (Optional)Feuermelde Modul 3(erforderlich fr 6 Schleifen)VDR Modul(Optional)Drucker Modul(Optional)Feuermelde Modul 4(erforderlich fr 8 Schleifen)Ausgangs Modul 2(Optional) OPERATION MANUAL FIREALARMSYSTEM AFMS-3000 1.2 Data storing Configuration data, the menu texts, the fire and fault messages are on a SD-memory card in Text files stored. The SD-memory card is equipped with a FAT16-Dateisystem. The data up the SD-card can be worked on thus with usual PC hard and software. The text files with configuration data and menu texts it is developed in such a way with the fact that it eff
收藏 下载该资源
网站客服QQ:2055934822
金锄头文库版权所有
经营许可证:蜀ICP备13022795号 | 川公网安备 51140202000112号