资源预览内容
第1页 / 共3页
第2页 / 共3页
第3页 / 共3页
亲,该文档总共3页全部预览完了,如果喜欢就下载吧!
资源描述
自动喷淋灭火系统设备月自动喷淋灭火系统设备月/ /季检查表季检查表 主管: 工程师 : 检测人员:_前次检查日期: (Date of Last Examination) 检测日期: (Date of Examination) 评估危害风险之判断基准如下:评估危害风险之判断基准如下:“”-”-堪用、符合规定;堪用、符合规定;“1”-“1”-立即修正后堪用;立即修正后堪用;“2”-“2”-无法使用、损坏或未依安全规定且无法立即排无法使用、损坏或未依安全规定且无法立即排 除;除; “N”“N” -不适用。不适用。厂区(Site): 检测区域(Area): 第_月份 第_季度设备代号(Equipment NO.) 项次 Item检查内容(Questions)危害风险危害风险 (Hazardous(Hazardous Risk)Risk)异常状况改善措施异常状况改善措施 (ExplainExplain) A有备用喷头及扳钳?(Sprinkler wrench with spare sprinklers?)(0) (1) (2) (N) B检查时系统在正常防护状态(System in service on inspection)(0) (1) (2) (N)C喷头无泄漏、损坏或遭阻挡 (Head appears free from leakage, damage or obstruction)(0) (1) (2) (N)D湿式报警阀(Alarm check Valves:) D-1控制阀未受阻挡容易操作(control valves are accessible)(0) (1) (2) (N)D-2湿管系统上的表计状况良好并显示正常(二次侧高于一次侧供水压力?) (Gauges on wet-pipe system in good condition and showing normal system pressure?)(0) (1) (2) (N)D-3是否依照设计基准维持压力? (Maintaining downstream pressure per design criteria?)(0) (1) (2) (N)D-4外表无损伤? (Free from physical damage?)(0) (1) (2) (N)D-5全部阀的开关位置正确(All Valves in correct open or closed position)(0) (1) (2) (N)D-6延迟器和排水管无滴漏?(No leakage from retarding chamber or drains?)(0) (1) (2) (N)D-7控制阀可开/监视开关可正常作动 (control valve lock can open/temper switches appear operational)(0) (1) (2) (N)D-8湿式报警阀之水流指示器传讯正常(Water flow switch operational)(0) (1) (2) (N)D-9湿式报警阀之水力警铃作动正常(Bell is operating normal)(0) (1) (2) (N)自动喷淋灭火系统设备月自动喷淋灭火系统设备月/ /季检查表季检查表 主管: 工程师 : 检测人员:_前次检查日期: (Date of Last Examination) 检测日期: (Date of Examination) 评估危害风险之判断基准如下:评估危害风险之判断基准如下:“”-”-堪用、符合规定;堪用、符合规定;“1”-“1”-立即修正后堪用;立即修正后堪用;“2”-“2”-无法使用、损坏或未依安全规定且无法立即排无法使用、损坏或未依安全规定且无法立即排 除;除; “N”“N” -不适用。不适用。D-10全部标示牌与标签还在?(All signage/identification tags in place?)(0) (1) (2) (N)项次 Item检查内容(Questions)危害风险危害风险 (Hazardous(Hazardous Risk)Risk)异常状况改善措施异常状况改善措施 (ExplainExplain) E末端查验管无漏水且开关操作正常(Water-flow test valve closed) (0) (1) (2) (N)F测试结果如先前的差不多?(Are results comparable to previous test?)(0) (1) (2) (N)G是否通过水流警报装置测试?(Water-flow alarm devices passed tests?)(0) (1) (2) (N)H将控制阀(OS&Y 和齿轮作动之指示蝴蝶阀除外)开至感觉到紧迫,再回转 1/4 Control valves (except OS&Y and gear-operated indicating butterfly valves) opened until spring or torsion is felt in the rod, then closed back one-quarter turn(0) (1) (2) (N)I阀之监视开关显示有作动?(Valve supervisory switches indicate movement?)(0) (1) (2) (N)J压力表作动正常(Gauges operating is normal)(0) (1) (2) (N) K水流警报装置反应灵敏(Water flow alarm devices activated)(0) (1) (2) (N) L供水系统过滤器及滤材是干净的(Strainers and filters cleaned)(0) (1) (2) (N) M防护区外水力警铃有作动 (Exterior building Alarms operate:)(0) (1) (2) (N)N防灾中心是否收到讯号(Did alarm supervisory company receive signal:)(0) (1) (2) (N)O警报面盘是否复归 (Did alarm panel reset:)(0) (1) (2) (N) P警报面盘无异常讯号(Alarm panel clear:)(0) (1) (2) (N) R检查完系统回复使用(Systems left in service)(0) (1) (2) (N) Q喷淋水泵结合器:Fire Department ConnectionsQ-1软管接头与快速接口无损坏且转动顺畅? (Couplings and swivels not damaged and rotate smoothly?)(0) (1) (2) (N)自动喷淋灭火系统设备月自动喷淋灭火系统设备月/ /季检查表季检查表 主管: 工程师 : 检测人员:_前次检查日期: (Date of Last Examination) 检测日期: (Date of Examination) 评估危害风险之判断基准如下:评估危害风险之判断基准如下:“”-”-堪用、符合规定;堪用、符合规定;“1”-“1”-立即修正后堪用;立即修正后堪用;“2”-“2”-无法使用、损坏或未依安全规定且无法立即排无法使用、损坏或未依安全规定且无法立即排 除;除; “N”“N” -不适用。不适用。Q-2栓塞、盖子、标示牌及垫片还在且无损坏? (Plugs or caps, Identification signs, gaskets in place and undamaged?)(0) (1) (2) (N)洒水系统主排水测试:Sprinkler system main drain test:末端试水测试 Water-flow test表压力Static Pressure湿式报警阀编号 Alarm check valve No.一次侧表压 (Sprinkler supply gauge)二次侧表压 (Sprinkler. system gauge)放水测试正 常 Drain test警铃作动 Alarm actuated静压动压水流作动时间 Alarm actuated time所有讯号正常 Signal to panel Is normalYes NoYes sec NoYes NoYes NoYes sec NoYes NoYes NoYes sec NoYes NoYes NoYes sec NoYes NoYes NoYes sec NoYes NoYes NoYes sec NoYes NoYes NoYes sec NoYes NoYes NoYes sec NoYes No自动喷淋灭火系统设备月自动喷淋灭火系统设备月/ /季检查表季检查表 主管: 工程师 : 检测人员:_前次检查日期: (Date of Last Examination) 检测日期: (Date of Examination) 评估危害风险之判断基准如下:评估危害风险之判断基准如下:“”-”-堪用、符合规定;堪用、符合规定;“1”-“1”-立即修正后堪用;立即修正后堪用;“2”-“2”-无法使用、损坏或未依安全规定且无法立即排无法使用、损坏或未依安全规定且无法立即排 除;除; “N”“N” -不适用。不适用。Yes NoYes sec NoYes No
收藏 下载该资源
网站客服QQ:2055934822
金锄头文库版权所有
经营许可证:蜀ICP备13022795号 | 川公网安备 51140202000112号