资源预览内容
第1页 / 共6页
第2页 / 共6页
第3页 / 共6页
第4页 / 共6页
第5页 / 共6页
第6页 / 共6页
亲,该文档总共6页全部预览完了,如果喜欢就下载吧!
资源描述
打开交换机端口,查看 ip 地址首先等入交换机ip 192.168.70.129 brocade8Gb:USERID switchshow switchName: brocade8Gb switchType: 73.6 switchState: Online switchMode: Native switchRole: Principal switchDomain: 1 switchId: fffc01 switchWwn: 10:00:00:27:f8:66:79:03 zoning: OFF switchBeacon: OFF Index Port Address Media Speed State Proto = 0 0 010000 id N8 No_Light FC Disabled (Persistent) 1 1 010100 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:20 2 2 010200 cu N8 Online FC F-Port 10:00:00:90:fa:17:dd:d2 3 3 010300 cu N8 Online FC F-Port 10:00:00:90:fa:17:db:a0 4 4 010400 cu N8 Online FC F-Port 10:00:00:90:fa:17:33:1a 5 5 010500 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:28 6 6 010600 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:80 7 7 010700 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:48 8 8 010800 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:02 9 9 010900 cu N8 Online FC F-Port 10:00:00:90:fa:17:dd:2a 10 10 010a00 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:e6 11 11 010b00 cu N8 Online FC F-Port 10:00:00:90:fa:17:30:dc 12 12 010c00 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:10 13 13 010d00 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:0a 14 14 010e00 cu N8 Online FC F-Port 10:00:00:90:fa:17:33:82 15 15 010f00 id N8 No_Light FC Disabled (Persistent) 16 16 011000 - N8 No_Module FC Disabled (Persistent) 17 17 011100 - N8 No_Module FC Disabled (Persistent) 18 18 011200 - N8 No_Module FC Disabled (Persistent) 19 19 011300 - N8 No_Module FC Disabled (Persistent) brocade8Gb:USERID version 查看版本Kernel: 2.6.14.2 Fabric OS: v6.4.2b4 Made on: Thu Aug 9 21:10:00 2012 Flash: Fri Mar 15 14:33:49 2013 BootProm: 1.0.9 brocade8Gb:USERID switchdisable 关闭交换机模式brocade8Gb:USERID ag -modeenable开启 ag 模式WARNING: Access Gateway mode changes the standard behavior of the switch. Please check Access Gateway Administrators Guide before proceeding. Enabling agmode will remove all the configuration data on the switch including zoning configuration and security database. Please backup your configuration using configupload. This operation will reboot the switch. Do you want to continue? (yes, y, no, n): no y这个时候会提示重新启动Access Gateway mode was enabled successfully Switch is being rebooted. 客户只有在0 号段口上有一根尾纤,这里做的都是把端口全部绑定在0 号口上由于关闭了交换机模式,交换机上无法再显示wwn 号了 . brocade8Gb:USERID switchshow switchName: brocade8Gb switchType: 73.6 switchState: Online switchMode: Access Gateway Mode switchWwn: 10:00:00:27:f8:66:bd:d8 switchBeacon: OFF Index Port Address Media Speed State Proto = 0 0 010000 id N8 No_Light FC 1 1 010100 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 2 2 010200 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 3 3 010300 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 4 4 010400 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 5 5 010500 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 6 6 010600 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 7 7 010700 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 8 8 010800 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 9 9 010900 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 10 10 010a00 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 11 11 010b00 cu AN No_Sync FC 12 12 010c00 cu AN No_Sync FC 13 13 010d00 cu AN No_Sync FC 14 14 010e00 cu AN No_Sync FC 15 15 010f00 id N8 No_Light FC 16 16 011000 - N8 No_Module FC 17 17 011100 - N8 No_Module FC 18 18 011200 - N8 No_Module FC 19 19 011300 - N8 No_Module FC brocade8Gb:USERID LOCAL : SEND0: window-change (rows: 24, cols: 80) brocade8Gb:USERID ag mapshow 这个是默认的设置N_Port Configured_F_Ports Current_F_Ports Failover Failback PG_ID PG_Name - 0 1;2 None 1 1 0 pg0 15 3;4 None 1 1 0 pg0 16 5;6;7 None 1 1 0 pg0 17 8;9 None 1 1 0 pg0 18 10;11 None 1 1 0 pg0 19 12;13;14 None 1 1 0 pg0 - brocade8Gb:USERID ag -mapdel 15 “3;4“ F_Port to N_Port mapping has been updated successfully brocade8Gb:USERID ag -mapdel 16 “5;6;7“ F_Port to N_Port mapping has been updated successfully brocade8Gb:USERID ag -mapdel 17 “8;9“ F_Port to N_Port mapping has been updated successfully brocade8Gb:USERID ag -mapdel 18 “10;11“ F_Port to N_Port mapping has been updated successfully brocade8Gb:USERID ag -mapdel 19 “12;13;14“ F_Port to N_Port mapping has been updated successfully brocade8Gb:USERID ag -mapadd 0“3;4;5;6;7;8;9;10;11;12;13;14“ 要注意空格USAGE: ag -mapadd “ Adds specified list of F_Ports to the mapping for a given N_Port. It will add the current to the existing mappings if any for that N_Port. An F_Port cannot be mapped to more than one N_Port at the same time brocade8Gb:USERID ag -mapadd 0“3;4“ USAGE: ag -mapadd “ Adds specified list of F_Ports to the mapping for a given N_Port. It will add the current to the existing mappings if any for that N_Port. An F_Port cannot b
收藏 下载该资源
网站客服QQ:2055934822
金锄头文库版权所有
经营许可证:蜀ICP备13022795号 | 川公网安备 51140202000112号