Voltage measurement kit for personal computer Oct-20-2001 a kit can measure four individual voltage inputs and the associated program can record the data into the file report.txt in Windows. the kit has two digital outputs for the pass-or-fail out, one is the AND function for the measurement 1 and 2 ,the other is the AND function for the measurement 3 and 4. In addition, the kit has two digital inputs for the data recording management, one is to save the file continuously while the input is low, the other is to save the file only when the input is transiting from high to low. the sub-VI (option 00B) is available for LabView programmer, also the advanced software dll file (option 00C) is provided, then user can use those files to control the kit with other program platforms which are preferred.本裝置能量測4組個別電壓輸入,且透過其程式將量測資料記錄於檔案report.txt於Windows系統下. 此裝置有兩組判別pass-or-fail的數位輸出,其中一組是針對量測電壓1及2的AND結果值, 另外一組是針對量測電壓3及4的AND結果值. 這裝置還有兩組數位輸入,一組當輸入是low時量測資料會連續記錄入檔案,另一組則只當輸入從high變 low才記錄該量測資料. Option 00B 提供sub-VI 程式給LabView 程式開發者, option 00C 提供.dll程式給任何其他程式平臺開發者來控制此裝置.Install procedure:1. copy the files vmk.exe and lkut.txt into c:vmk 2. connect RS232 cable to the kit.3. run the program vmk.exeif you have any questions about the program and kit, please contact us (lily.cnmsa.hinet.net). 安裝程序:1. 拷貝vmk.exe 和 lkut.txt 到路徑 c:vmk2. 連接RS232線到電腦.3. 執行vmk.exe程式. 假如有任何問題請寫 E-mail至lily.cnmsa.hinet.netFig1. When the program starts, it searches for the kit automatically by the RS232, If it cant find the kit, it will show the warning message.Fig1. 當程式執行,它會透過RS232尋找控制裝置,如果找不到會顯現警告訊息.Fig2. First you can switch on or off of each measurement by pushing the enable buttons. There are four individual measurements ( F1 to F4 ) for four inputs. In each measurement you can set the high and low limits for the output. if the measurement passes then the indicator at the left side of the enable button turn green, otherwise red.Fig2. 首先你能按enable鈕打開或關閉各項量測.共4項量測針對4個輸入,每項 量測都可設定high 及low判斷界線,假如通過則enable左邊燈號亮綠色, 否則為紅色.Fig3. Pull down the AVE factor selector to select the average factor.Fig3. 拉下AVE factor鈕可選擇平均值設定.Fig4. Pull down the function selector to select the calculation functions for the outputs.Fig4. 拉下功能選擇鈕可選擇對輸出對輸入的計算功能.Fig5. in measurement 3,4 there has an additional calibration factor, it helps match the real input voltages with the outputs shown. But in measurement 1,2 they are calibrated from the look up table in the file lkut.txt, the advantage of that is able to transfer the real inputs into any nonlinear data as you like, because the look up table of the lkut.txt file can be defined by user. Fig5. 量測3及4有額外的校正參數可設定,此可助調整顯示的輸出與輸入實質 的吻合.但量測1及2是以查表法來校正, 查表檔案為lkut.txt, 內容可由使 用者自行設定,其優點是可轉換輸入值成任何非線性關係之輸出值.Fig6. Here shows the four A/D converters status.the bar lines should vary within the range during measuring to indicate the data is not saturation or cut off.Fig6. 有4條長線顯示A/D轉換器的狀態, 量測時線長會隨輸入變化,但須在此 頭尾區間內,才表示量測未超出A/D轉換的截止或飽和界限.A/D and digital I/O interface external power supply RS 232 interfaceA/D轉換和數位輸出入界面 外部電源輸入口 RS 232界面Fig7. The voltage measurement kit. (a). external power supply (Vs) : 39V, notice the center pin is “-“ .(b). A/D and digital I/O interface : there are 4 A/D converters which input voltage range is from 0 to Vs if external power is applied, or from 0 to the voltage of the RS232 (from PC) if external power is not applied. 2 digital inputs and 2 digital outputs are TTL with the logic voltage from 0 to Vs or RS232s voltage. (c). RS 232 interface : should be connected to PC. Fig7. (a)外部電源供應Vs由3到9V,注意中心pin為負極. (b)A/D及數位輸出入的電壓範圍是由0到Vs, 若外部無電源供應,範圍則 從0到電腦給RS232的電壓. (c) RS232須接至電腦.The connection of I/O interface :Top view from fig.7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1. NC2. NC3. GND4. GND5. GND6. NC7. NC8. NC9. GND10. AD1 input11. AD2 input12. AD3 input13. AD4 input14. digital O/P 1 ( measurement 1 AND measurement 2 )15. digital O/P 2 ( measurement 3 AND measurement 4 )16. digital I/P 1 (the file saving function , once at each transition from high to low ) 17. digital I/P 2 (the continuously file saving function, active low )18. GND electrical characters :AD input impedance 47 k ohmdigital input impedanc
收藏 下载该资源
网站客服QQ:2055934822
金锄头文库版权所有
经营许可证:蜀ICP备13022795号 | 川公网安备 51140202000112号